Popular Posts

Oct 22, 2020

Script to Update iLO Firmware

 Script to Update iLO Firmware


APPLIES TO :  HP iLO

ISSUE :  How to update iLO firmware for many servers in one go. 

GOAL :  Automate with scripts to update the iLO firmware. 

SOLUTION :  Create scripts using HP provided tools to automate the iLO firmware upgrade. 

Prerequisites :   A Linux jump server which can reach all the console IP's
                              or any Linux terminal - preferably Cygwin installed in your laptop.
                              Download Firmware rpm file
                              Download linux-LOsamplescripts5.30.0.tgz tool from HP

1. Download the rpm file of firmware.
            Link to down load the iLO Firmware version 2.30 (firmware-ilo5-2.30-1.1.x86_64.rpm)

2. Download HP tool to pass on the firmware in xml
            Download link linux-LOsamplescripts5.30.0.tgz

3. Extract the HP tool to get the Update_Firmware.xml file and locfg.pl file
            tar zxvf linux-LOsamplescripts5.30.0.tgz

4. Extract the rpm file to get the binary file
            $ rpm2cpio firmware-ilo5-2.30-1.1.x86_64.rpm | cpio -idmv
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/.cpq_package.inc
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/.setup
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/CP038707.xml
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/hpsetup
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.30-1.1/ilo5_230.bin
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/payload.json
            ./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.10-1.1/setup
            ./usr/lib/x86_64-linux-gnu/hp-scexe-compat
            cpio: ./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP038707.scexe not created: newer or same age version exists
            ./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP038707.scexe
            ./usr/lib/x86_64-linux-gnu/scexe-compat
            cpio: ./usr/lib/x86_64-linux-gnu/scexe-compat/CP038707.scexe not created: newer or same age version exists
            ./usr/lib/x86_64-linux-gnu/scexe-compat/CP038707.scexe
            66357 blocks
            

5. Edit the file Update_Firmware.xml and provide the path of binary file which is extracted from the rpm
            <UPDATE_RIB_FIRMWARE IMAGE_LOCATION="/home/judi/ilo5_230.bin"/>

6. Execute manually in one server to test the xml file and firmware update.
            perl /home/judi/linux-LOsamplescripts5.30.0/locfg.pl -s 192.168.1.11 -f /home/judi/windows-LOsamplescripts4.50.0/Update_Firmware.xml -u ilousername -p ilopasswd

7. Now check the firmware version of that server.
            curl -ks "https://192.168.1.10/redfish/v1/Managers/1/" -k -u ilousername:ilopasswd | python -m json.tool | grep "FirmwareVersion"

8. Upon confirmation the functionality, write a script to update the firmware to all servers
            for i in `cat /home/judi/server_list`; do
                    perl /home/judi/linux-LOsamplescripts5.30.0/locfg.pl -s $i -f /home/judi/windows-LOsamplescripts4.50.0/Update_Firmware.xml -u ilousername -p ilopasswd
                    if [ $? -eq 0 ] ; then
                       echo "$i         - Done" >> /home/judi/log.out
                    else
                       echo "$i         - NOT" >> /home/judi/log.out
                    fi
            done 

9. Check the log.out file to know the status of the firmware update


~Judi~